A new proportional counter type, baptized Multiple Cell Proportional Counter (MCPC), intended for continuous airborne radon activity measurements is described and its operation principle presented. This gas-flow proportional counter, consisting in a pile-up of 20 separate proportional counters elements, uses an argon-propane (1%) as a binary gas mixture to which is admixed an appropriate fraction of ambient air, in which radon activity concentration has to be continuously measured through a periodic counting of the áparticles emitted by 222Rn and its short-lived decay products within the sensitive volume. A Monte Carlo simulation code, RADON-MCPC, which takes into account the major physical processes that determine directly the detector performances, has been written and used for design optimization purposes. According to preliminary design calculations the MCPC model, should achieve a radon counting efficiency greater than 100 %. The simulation results show that the admixture of 10 % of ambient air seems to be sufficient to continuously assess radon concentration levels ranging from about 15 Bq/m3 up to 1.5 105 kBq/m3 for an integral counting period of 10 minutes, when setting the energy discrimination at 250 keV. The expected radon sensitivity is about 11 cpm /100 Bq⋅m-3, achieving thus a measurement accuracy of ± 10 Bq/m3 at a mean radon concentration level of 100 Bq/m3 with a detector time response of 10 min. The preliminary experimental á spectra registered show a great agreement with those obtained through the simulation code.

A Multiple Cell Proportional Counter for Continuous Airborne Radon Assessment

Mazed, Dahmane
2007

Abstract

A new proportional counter type, baptized Multiple Cell Proportional Counter (MCPC), intended for continuous airborne radon activity measurements is described and its operation principle presented. This gas-flow proportional counter, consisting in a pile-up of 20 separate proportional counters elements, uses an argon-propane (1%) as a binary gas mixture to which is admixed an appropriate fraction of ambient air, in which radon activity concentration has to be continuously measured through a periodic counting of the áparticles emitted by 222Rn and its short-lived decay products within the sensitive volume. A Monte Carlo simulation code, RADON-MCPC, which takes into account the major physical processes that determine directly the detector performances, has been written and used for design optimization purposes. According to preliminary design calculations the MCPC model, should achieve a radon counting efficiency greater than 100 %. The simulation results show that the admixture of 10 % of ambient air seems to be sufficient to continuously assess radon concentration levels ranging from about 15 Bq/m3 up to 1.5 105 kBq/m3 for an integral counting period of 10 minutes, when setting the energy discrimination at 250 keV. The expected radon sensitivity is about 11 cpm /100 Bq⋅m-3, achieving thus a measurement accuracy of ± 10 Bq/m3 at a mean radon concentration level of 100 Bq/m3 with a detector time response of 10 min. The preliminary experimental á spectra registered show a great agreement with those obtained through the simulation code.
14-mag-2007
Italiano
Electron attachment
Gas gain
Monte Carlo simulation
Proportional Counters
Radon activity concentration
Curzio, Giorgio
File in questo prodotto:
File Dimensione Formato  
APPENDIX_A.pdf

embargo fino al 15/03/2047

Tipologia: Altro materiale allegato
Dimensione 142.59 kB
Formato Adobe PDF
142.59 kB Adobe PDF
APPENDIX_B.pdf

accesso aperto

Dimensione 43 kB
Formato Adobe PDF
43 kB Adobe PDF Visualizza/Apri
APPENDIX_C.pdf

accesso aperto

Dimensione 41.03 kB
Formato Adobe PDF
41.03 kB Adobe PDF Visualizza/Apri
APPENDIX_D.pdf

accesso aperto

Dimensione 86.75 kB
Formato Adobe PDF
86.75 kB Adobe PDF Visualizza/Apri
CONCLUSION.pdf

accesso aperto

Dimensione 69.17 kB
Formato Adobe PDF
69.17 kB Adobe PDF Visualizza/Apri
HEADING_PAGES.pdf

accesso aperto

Dimensione 91.3 kB
Formato Adobe PDF
91.3 kB Adobe PDF Visualizza/Apri
INTRODUCTION.pdf

accesso aperto

Dimensione 99.72 kB
Formato Adobe PDF
99.72 kB Adobe PDF Visualizza/Apri
SECTION_I.pdf

accesso aperto

Dimensione 157.44 kB
Formato Adobe PDF
157.44 kB Adobe PDF Visualizza/Apri
SECTION_II.pdf

accesso aperto

Dimensione 447.07 kB
Formato Adobe PDF
447.07 kB Adobe PDF Visualizza/Apri
SECTION_III.pdf

accesso aperto

Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF Visualizza/Apri
SECTION_IV.pdf

accesso aperto

Dimensione 2.37 MB
Formato Adobe PDF
2.37 MB Adobe PDF Visualizza/Apri
SECTION_V.pdf

accesso aperto

Dimensione 685.18 kB
Formato Adobe PDF
685.18 kB Adobe PDF Visualizza/Apri
TABLE_OF_CONTENTS.pdf

accesso aperto

Dimensione 77.79 kB
Formato Adobe PDF
77.79 kB Adobe PDF Visualizza/Apri

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14242/144947
Il codice NBN di questa tesi è URN:NBN:IT:UNIPI-144947