This research conducts a detailed techno-economic assessment (TEA) and process modelling of CO2 capture technologies to decarbonize the cement industry. The study uses Aspen Plus for thermodynamic modelling and a bottom-up economic evaluation methodology. The primary objective is to evaluate two main decarbonization pathways for future full-scale application: standalone post-combustion capture (PCC) using amine solvents, and a novel hybrid capture technology that combines partial oxyfuel calcination and a CO2 purification Unit (CPU) with PCC to treat rotary kiln effluents. The rationale for selecting this configuration for cement production is the feasibility of retrofitting oxyfuel calcination, enabling the capture, of approximately 80% of the generated CO2. The remaining CO2 emissions, originating from the rotary kiln and vented from the CO2 purification unit downstream of the oxyfuel calciner are addressed through a conventional PCC process. Furthermore, the research prepares the ground for upcoming TRL 7-8 piloting activities, foreseen in the EU HORIZON HERCCULES project, by providing the conceptual process design for two pilot plants aimed at demonstrating the proposed hybrid solution. The thesis also includes some results of the experimental campaigns carried out on the PCC pilot plant with cement flue gases. Regarding standalone PCC configuration, this study systematically evaluates both conventional and electrified steam production strategies, while targeting an overall CO2 removal efficiency of at least 95%. The conventional baseline assumes the heat supply for monoethanolamine (MEA) regeneration is provided by a natural gas (NG) fired boiler, whose off-gases are co-treated in the CO2 capture plant. Three integration schemes were analyzed: a tail-end configuration located downstream of the raw mill of the cement plant; an integrated configuration upstream of the raw mill utilizing a single absorber for both cement and NG boiler flue gases; and an integrated configuration identical in location but featuring separate absorbers. The TEA identified the second option as the one with the lowest CO2 avoidance costs. Compared to the tail-end configuration, it handles a smaller volume of flue gas with a higher CO2 concentration, resulting in lower CAPEX and OPEX. The second case study outperforms also the third one since it avoids the higher capital costs associated with the dual-absorber setup. This analysis confirms that NG consumption drives conventional PCC costs, accounting for 26-35% of the CO2 avoidance cost. To eliminate the economic and environmental penalty of the NG boiler, advanced regeneration strategies exploiting low-temperature waste heat from the cement plant and capture unit were evaluated, including Lean Vapor Compression (LVC) and High-Temperature Heat Pumps (HTHPs). The analysis demonstrates that recovering approximately 60 MW of waste heat (13% from the cement plant, 87% from the capture unit) and upgrading it via heat pumps with a COP of around 2.7 can fully electrify solvent regeneration. The most promising techno-economic solution integrates an HTHP with a Mechanical Vapor Recompression (MVR) cascade and LVC. This configuration yields a specific electricity consumption of 474 kWh/tCO2 and minimizes the CO2 avoidance cost to 125.9 €/tCO2, representing a 16% reduction compared to the NG baseline. The CAPEX is estimated at 171.5 M€ (1.8 M€2024/tphCO2), achieving a 32% reduction in the incremental clinker cost. Sensitivity analyses reveal that while HTHP cost competitiveness diminishes as electricity prices rise, they iii remain viable over a wide range of conditions, presenting an additional benefit of reducing upstream energy consumption and methane leakages across the NG supply chain. The hybrid CO2 capture process proposed in this thesis features a design combining partial oxyfuel combustion + CPU in the pre-calciner with an MEA-based PCC unit applied to the rotary kiln flue gases and CPU vent gas. A parametric analysis identified a three-stage suspension preheater for both the kiln and calciner lines, operating with 50% O2 concentration in the oxidant stream, as the most efficient setup for retrofitting the partial oxyfuel calcination. This design exploits profound thermal synergies, as the waste heat available from the plant provides approximately 5.5 MJ/kgCO2, which is entirely sufficient to meet the thermal demand for solvent regeneration in the MEA unit. Consequently, the capture process achieves thermal autonomy without auxiliary steam generation, requiring electric power only for the O2 supply and the CO2 compressors. The hybrid configuration enables ultra-high CO2 reduction rates of up to 99.7% and economically outperforms the reference plant without capture under a carbon taxation scenario of 150 €/tCO2, achieving an incremental clinker cost of 85.6 €/tclk and a CO2 avoidance cost of 103.6 €/tCO2. The integration of alternative fuels further enhances these performances; switching from coal to 100% refuse-derived fuels (RDF) allows the cement plant to operate as a net-negative-emission facility, achieving a footprint of -181.9 kgCO2/tclk. A comprehensive comparison is conducted against other state-of-the-art technologies, revealing that while the standalone partial oxyfuel setup (with no PCC on the kiln effluents) yields a marginally lower absolute cost of CO2 avoidance, the hybrid process becomes the solution with the lowest incremental clinker cost when the carbon tax exceeds 115 €/tCO2. The higher CAPEX and OPEX of the hybrid's PCC unit are effectively offset by the significantly larger volume of captured CO2, minimizing residual emissions and lowering carbon tax related costs. Ultimately, the hybrid process proves to be substantially more economically viable and energy-efficient than standalone MEA-based end-of-pipe solutions. To support the HERCCULES project's detailed engineering phase and upcoming experimental campaigns, process and thermodynamic modelling, as well as experimental data elaboration have been carried out for a TRL 7 PCC demonstration unit. The pilot plant is designed to treat real cement flue gases, producing 125 kg/h of liquid CO2 at > 99% v/v purity. By integrating absorber intercooling, rich solvent split, and LVC, it reports an 18% reduction in equivalent energy consumption compared to conventional configurations. Commissioning and the first test campaign using 30 wt% MEA were successfully completed, with the plant operating for over 800 hours and producing more than 20 tonnes of liquid CO2. Twenty-three steady-state operating points confirmed excellent capture performance, with CO2 capture rates above 99.5% and peaks close to 99.8%. The liquefied CO2 met industrial and ISBT quality requirements, showing very low impurity levels. The campaign also highlighted solvent degradation with time, which may have contributed to slightly lower performance in later tests. Comparison with the Aspen Plus model showed good agreement for key process parameters and overall operating trends. The estimated reboiler duty was not in line with the Aspen simulation and state-of.the-art MEA processes. The future tests will focus on improving the plant thermal balance, refining solvent regeneration estimates, and testing advanced process configurations and operating conditions.

Questa ricerca conduce una dettagliata valutazione tecnico-economica (TEA) e la modellazione di processo delle tecnologie di cattura della CO2 per la decarbonizzazione dell'industria del cemento. Lo studio utilizza Aspen Plus per la modellazione termodinamica e una metodologia di valutazione economica di tipo bottom-up. L'obiettivo principale è valutare due percorsi fondamentali di decarbonizzazione per future applicazioni su scala industriale: la cattura post-combustione (PCC) stand-alone che utilizza solventi amminici, e una nuova tecnologia di cattura ibrida che combina la calcinazione in ossicombustione parziale e un'unità di purificazione della CO2 (CPU) con la PCC per trattare gli effluenti del forno rotativo. La logica alla base della scelta di questa configurazione per la produzione di cemento è la fattibilità del retrofit alla calcinazione oxyfuel, che consente la cattura di circa l'80% della CO2 generata. Le restanti emissioni di CO2, provenienti dal forno rotativo e dai gas di sfiato dell'unità di purificazione della CO2 a valle del calcinatore oxyfuel, vengono gestite attraverso un processo PCC convenzionale. Inoltre, la ricerca prepara il terreno per le imminenti attività pilota a livello di TRL 7-8, previste nell'ambito del progetto europeo HORIZON HERCCULES, fornendo la progettazione concettuale di processo per due impianti pilota volti a dimostrare la soluzione ibrida proposta. La tesi include anche alcuni risultati delle campagne sperimentali effettuate sull'impianto pilota PCC con fumi di cementeria. Per quanto riguarda la configurazione PCC stand-alone, questo studio valuta sistematicamente sia le strategie convenzionali che quelle elettrificate per la produzione di vapore, puntando a un'efficienza complessiva di rimozione della CO2 di almeno il 95%. Lo scenario di base convenzionale presuppone che l'apporto di calore per la rigenerazione della monoetanolammina (MEA) sia fornito da una caldaia a gas naturale (NG), i cui gas di scarico vengono co-trattati nell'impianto di cattura della CO2. Sono stati analizzati tre schemi di integrazione: una configurazione tail-end situata a valle del mulino del crudo dell'impianto di cemento; una configurazione integrata a monte del mulino del crudo che utilizza un singolo assorbitore sia per i fumi della cementeria che per quelli della caldaia a gas naturale; e una configurazione integrata identica per ubicazione ma caratterizzata da assorbitori separati. La TEA ha identificato la seconda opzione come quella con il minor costo della CO2 evitata. Rispetto alla configurazione tail-end, essa gestisce un volume inferiore di fumi con una maggiore concentrazione di CO2, con conseguente riduzione di CAPEX e OPEX. Il secondo caso studio supera anche il terzo, in quanto evita i maggiori costi in conto capitale associati alla configurazione a doppio assorbitore. Questa analisi conferma che il consumo di gas naturale è il principale fattore trainante dei costi nella PCC convenzionale, rappresentando il 26-35% del costo della CO2 evitata. Per eliminare la penalizzazione economica e ambientale della caldaia a gas naturale, sono state valutate strategie di rigenerazione avanzate che sfruttano il calore di scarto a bassa temperatura proveniente dalla cementeria e dall'unità di cattura, tra cui la Lean Vapor Compression (LVC) e le Pompe di Calore ad Alta Temperatura (HTHP). L'analisi dimostra che recuperare circa 60 MW di calore di scarto (13% dalla cementeria, 87% dall'unità di cattura) e innalzarne il livello termico tramite pompe di calore con un COP di circa 2,7 può elettrificare completamente la rigenerazione del solvente. La soluzione tecnico-economica più promettente integra un'HTHP con una Ricompressione Meccanica del Vapore (MVR) e LVC. Questa configurazione produce un consumo specifico di energia elettrica di 474 kWh/tCO2 e minimizza il costo della CO2 evitata a 125,9 €/tCO2, rappresentando una riduzione del 16% rispetto alla baseline a gas naturale. Il CAPEX è stimato in 171,5 M€ (1,8 M€2024/tphCO2), ottenendo una riduzione del 32% del costo incrementale del clinker. Le analisi di sensibilità rivelano che, sebbene la competitività in termini di costo delle HTHP diminuisca all'aumentare dei prezzi dell'energia elettrica, esse rimangono valide in un'ampia gamma di condizioni, presentando l'ulteriore vantaggio di ridurre il consumo energetico a monte e le perdite di metano lungo la filiera di approvvigionamento del gas naturale. Il processo ibrido di cattura della CO2 proposto in questa tesi presenta un design che combina la combustione oxyfuel parziale e la CPU nel precalcinatore con un'unità PCC basata su MEA applicata ai fumi del forno rotativo e ai gas di sfiato della CPU. Un'analisi parametrica ha identificato un preriscaldatore a sospensione a tre stadi per entrambe le linee (forno e calcinatore), operante con una concentrazione di O2 del 50% nella corrente ossidante, come l'assetto più efficiente per il retrofit alla calcinazione oxyfuel parziale. Questo design sfrutta profonde sinergie termiche, poiché il calore di scarto disponibile dall'impianto fornisce circa 5,5 MJ/kgCO2, una quantità del tutto sufficiente per soddisfare il fabbisogno termico per la rigenerazione del solvente nell'unità ad MEA. Di conseguenza, il processo di cattura raggiunge l'autonomia termica senza la generazione ausiliaria di vapore, richiedendo energia elettrica esclusivamente per la fornitura di O2 e per i compressori di CO2. La configurazione ibrida consente tassi di riduzione della CO2 ultra-elevati, fino al 99,7%, e supera economicamente l'impianto di riferimento senza cattura in uno scenario di carbon tax di 150 €/tCO2, ottenendo un costo incrementale del clinker di 85,6 €/tclk e un costo della CO2 evitata di 103,6 €/tCO2. L'integrazione di combustibili alternativi migliora ulteriormente queste prestazioni; il passaggio dal carbone al 100% di combustibili derivati dai rifiuti (RDF) permette alla cementeria di operare come un impianto a emissioni nette negative, raggiungendo un'impronta carbonica di -181,9 kgCO2/tclk. È stato condotto un confronto completo rispetto ad altre tecnologie allo stato dell'arte, rivelando che mentre la configurazione oxyfuel parziale stand-alone (senza PCC sugli effluenti del forno) porta a un costo assoluto della CO2 evitata marginalmente inferiore, il processo ibrido diventa la soluzione con il minor costo incrementale del clinker quando la carbon tax supera i 115 €/tCO2. I maggiori CAPEX e OPEX dell'unità PCC del sistema ibrido sono efficacemente compensati dal volume significativamente più ampio di CO2 catturata, minimizzando le emissioni residue e riducendo i costi legati alla tassa sul carbonio. In definitiva, il processo ibrido si dimostra un'opzione sostanzialmente più valida economicamente ed efficiente dal punto di vista energetico rispetto alle soluzioni end-of-pipe basate su MEA. Per supportare la fase di ingegneria di dettaglio del progetto HERCCULES e le imminenti campagne sperimentali, sono state eseguite la modellazione di processo e termodinamica, oltre all'elaborazione dei dati sperimentali, per un'unità dimostrativa PCC con TRL 7. L'impianto pilota è progettato per trattare fumi di cementeria reali, producendo 125 kg/h di CO2 liquida con una purezza > 99% v/v. Integrando absorber intercooling, rich solvent split e la LVC, si registra una riduzione del 18% del consumo energetico equivalente rispetto alle configurazioni convenzionali. Il commissioning e la prima campagna di test utilizzando MEA al 30% in peso sono state completate con successo, con l'impianto che ha operato per oltre 800 ore e prodotto più di 20 tonnellate di CO2 liquida. Ventitré punti operativi a regime stazionario hanno confermato eccellenti prestazioni, con tassi di cattura della CO2 superiori al 99,5% e picchi vicini al 99,8%. La CO2 liquefatta ha soddisfatto i requisiti di qualità industriali e ISBT, mostrando livelli di impurità molto bassi. La campagna ha inoltre evidenziato una degradazione del solvente nel tempo, che potrebbe aver contribuito a prestazioni leggermente inferiori nei test successivi. Il confronto con il modello in Aspen Plus ha mostrato un buon accordo in merito ai parametri di processo chiave e ai trend operativi generali. Il fabbisogno termico stimato al ribollitore non è risultato in linea con la simulazione in Aspen e con i processi ad MEA allo stato dell'arte. I test futuri si concentreranno sul miglioramento del bilancio termico dell'impianto, sull'affinamento delle stime per la rigenerazione del solvente e sulla sperimentazione di configurazioni di processo e condizioni operative avanzate.

Advancing ultra-low emission post-combustion and hybrid CO2 capture technologies for cement decarbonization

CREMONA, RICCARDO
2026

Abstract

This research conducts a detailed techno-economic assessment (TEA) and process modelling of CO2 capture technologies to decarbonize the cement industry. The study uses Aspen Plus for thermodynamic modelling and a bottom-up economic evaluation methodology. The primary objective is to evaluate two main decarbonization pathways for future full-scale application: standalone post-combustion capture (PCC) using amine solvents, and a novel hybrid capture technology that combines partial oxyfuel calcination and a CO2 purification Unit (CPU) with PCC to treat rotary kiln effluents. The rationale for selecting this configuration for cement production is the feasibility of retrofitting oxyfuel calcination, enabling the capture, of approximately 80% of the generated CO2. The remaining CO2 emissions, originating from the rotary kiln and vented from the CO2 purification unit downstream of the oxyfuel calciner are addressed through a conventional PCC process. Furthermore, the research prepares the ground for upcoming TRL 7-8 piloting activities, foreseen in the EU HORIZON HERCCULES project, by providing the conceptual process design for two pilot plants aimed at demonstrating the proposed hybrid solution. The thesis also includes some results of the experimental campaigns carried out on the PCC pilot plant with cement flue gases. Regarding standalone PCC configuration, this study systematically evaluates both conventional and electrified steam production strategies, while targeting an overall CO2 removal efficiency of at least 95%. The conventional baseline assumes the heat supply for monoethanolamine (MEA) regeneration is provided by a natural gas (NG) fired boiler, whose off-gases are co-treated in the CO2 capture plant. Three integration schemes were analyzed: a tail-end configuration located downstream of the raw mill of the cement plant; an integrated configuration upstream of the raw mill utilizing a single absorber for both cement and NG boiler flue gases; and an integrated configuration identical in location but featuring separate absorbers. The TEA identified the second option as the one with the lowest CO2 avoidance costs. Compared to the tail-end configuration, it handles a smaller volume of flue gas with a higher CO2 concentration, resulting in lower CAPEX and OPEX. The second case study outperforms also the third one since it avoids the higher capital costs associated with the dual-absorber setup. This analysis confirms that NG consumption drives conventional PCC costs, accounting for 26-35% of the CO2 avoidance cost. To eliminate the economic and environmental penalty of the NG boiler, advanced regeneration strategies exploiting low-temperature waste heat from the cement plant and capture unit were evaluated, including Lean Vapor Compression (LVC) and High-Temperature Heat Pumps (HTHPs). The analysis demonstrates that recovering approximately 60 MW of waste heat (13% from the cement plant, 87% from the capture unit) and upgrading it via heat pumps with a COP of around 2.7 can fully electrify solvent regeneration. The most promising techno-economic solution integrates an HTHP with a Mechanical Vapor Recompression (MVR) cascade and LVC. This configuration yields a specific electricity consumption of 474 kWh/tCO2 and minimizes the CO2 avoidance cost to 125.9 €/tCO2, representing a 16% reduction compared to the NG baseline. The CAPEX is estimated at 171.5 M€ (1.8 M€2024/tphCO2), achieving a 32% reduction in the incremental clinker cost. Sensitivity analyses reveal that while HTHP cost competitiveness diminishes as electricity prices rise, they iii remain viable over a wide range of conditions, presenting an additional benefit of reducing upstream energy consumption and methane leakages across the NG supply chain. The hybrid CO2 capture process proposed in this thesis features a design combining partial oxyfuel combustion + CPU in the pre-calciner with an MEA-based PCC unit applied to the rotary kiln flue gases and CPU vent gas. A parametric analysis identified a three-stage suspension preheater for both the kiln and calciner lines, operating with 50% O2 concentration in the oxidant stream, as the most efficient setup for retrofitting the partial oxyfuel calcination. This design exploits profound thermal synergies, as the waste heat available from the plant provides approximately 5.5 MJ/kgCO2, which is entirely sufficient to meet the thermal demand for solvent regeneration in the MEA unit. Consequently, the capture process achieves thermal autonomy without auxiliary steam generation, requiring electric power only for the O2 supply and the CO2 compressors. The hybrid configuration enables ultra-high CO2 reduction rates of up to 99.7% and economically outperforms the reference plant without capture under a carbon taxation scenario of 150 €/tCO2, achieving an incremental clinker cost of 85.6 €/tclk and a CO2 avoidance cost of 103.6 €/tCO2. The integration of alternative fuels further enhances these performances; switching from coal to 100% refuse-derived fuels (RDF) allows the cement plant to operate as a net-negative-emission facility, achieving a footprint of -181.9 kgCO2/tclk. A comprehensive comparison is conducted against other state-of-the-art technologies, revealing that while the standalone partial oxyfuel setup (with no PCC on the kiln effluents) yields a marginally lower absolute cost of CO2 avoidance, the hybrid process becomes the solution with the lowest incremental clinker cost when the carbon tax exceeds 115 €/tCO2. The higher CAPEX and OPEX of the hybrid's PCC unit are effectively offset by the significantly larger volume of captured CO2, minimizing residual emissions and lowering carbon tax related costs. Ultimately, the hybrid process proves to be substantially more economically viable and energy-efficient than standalone MEA-based end-of-pipe solutions. To support the HERCCULES project's detailed engineering phase and upcoming experimental campaigns, process and thermodynamic modelling, as well as experimental data elaboration have been carried out for a TRL 7 PCC demonstration unit. The pilot plant is designed to treat real cement flue gases, producing 125 kg/h of liquid CO2 at > 99% v/v purity. By integrating absorber intercooling, rich solvent split, and LVC, it reports an 18% reduction in equivalent energy consumption compared to conventional configurations. Commissioning and the first test campaign using 30 wt% MEA were successfully completed, with the plant operating for over 800 hours and producing more than 20 tonnes of liquid CO2. Twenty-three steady-state operating points confirmed excellent capture performance, with CO2 capture rates above 99.5% and peaks close to 99.8%. The liquefied CO2 met industrial and ISBT quality requirements, showing very low impurity levels. The campaign also highlighted solvent degradation with time, which may have contributed to slightly lower performance in later tests. Comparison with the Aspen Plus model showed good agreement for key process parameters and overall operating trends. The estimated reboiler duty was not in line with the Aspen simulation and state-of.the-art MEA processes. The future tests will focus on improving the plant thermal balance, refining solvent regeneration estimates, and testing advanced process configurations and operating conditions.
27-lug-2026
Inglese
Questa ricerca conduce una dettagliata valutazione tecnico-economica (TEA) e la modellazione di processo delle tecnologie di cattura della CO2 per la decarbonizzazione dell'industria del cemento. Lo studio utilizza Aspen Plus per la modellazione termodinamica e una metodologia di valutazione economica di tipo bottom-up. L'obiettivo principale è valutare due percorsi fondamentali di decarbonizzazione per future applicazioni su scala industriale: la cattura post-combustione (PCC) stand-alone che utilizza solventi amminici, e una nuova tecnologia di cattura ibrida che combina la calcinazione in ossicombustione parziale e un'unità di purificazione della CO2 (CPU) con la PCC per trattare gli effluenti del forno rotativo. La logica alla base della scelta di questa configurazione per la produzione di cemento è la fattibilità del retrofit alla calcinazione oxyfuel, che consente la cattura di circa l'80% della CO2 generata. Le restanti emissioni di CO2, provenienti dal forno rotativo e dai gas di sfiato dell'unità di purificazione della CO2 a valle del calcinatore oxyfuel, vengono gestite attraverso un processo PCC convenzionale. Inoltre, la ricerca prepara il terreno per le imminenti attività pilota a livello di TRL 7-8, previste nell'ambito del progetto europeo HORIZON HERCCULES, fornendo la progettazione concettuale di processo per due impianti pilota volti a dimostrare la soluzione ibrida proposta. La tesi include anche alcuni risultati delle campagne sperimentali effettuate sull'impianto pilota PCC con fumi di cementeria. Per quanto riguarda la configurazione PCC stand-alone, questo studio valuta sistematicamente sia le strategie convenzionali che quelle elettrificate per la produzione di vapore, puntando a un'efficienza complessiva di rimozione della CO2 di almeno il 95%. Lo scenario di base convenzionale presuppone che l'apporto di calore per la rigenerazione della monoetanolammina (MEA) sia fornito da una caldaia a gas naturale (NG), i cui gas di scarico vengono co-trattati nell'impianto di cattura della CO2. Sono stati analizzati tre schemi di integrazione: una configurazione tail-end situata a valle del mulino del crudo dell'impianto di cemento; una configurazione integrata a monte del mulino del crudo che utilizza un singolo assorbitore sia per i fumi della cementeria che per quelli della caldaia a gas naturale; e una configurazione integrata identica per ubicazione ma caratterizzata da assorbitori separati. La TEA ha identificato la seconda opzione come quella con il minor costo della CO2 evitata. Rispetto alla configurazione tail-end, essa gestisce un volume inferiore di fumi con una maggiore concentrazione di CO2, con conseguente riduzione di CAPEX e OPEX. Il secondo caso studio supera anche il terzo, in quanto evita i maggiori costi in conto capitale associati alla configurazione a doppio assorbitore. Questa analisi conferma che il consumo di gas naturale è il principale fattore trainante dei costi nella PCC convenzionale, rappresentando il 26-35% del costo della CO2 evitata. Per eliminare la penalizzazione economica e ambientale della caldaia a gas naturale, sono state valutate strategie di rigenerazione avanzate che sfruttano il calore di scarto a bassa temperatura proveniente dalla cementeria e dall'unità di cattura, tra cui la Lean Vapor Compression (LVC) e le Pompe di Calore ad Alta Temperatura (HTHP). L'analisi dimostra che recuperare circa 60 MW di calore di scarto (13% dalla cementeria, 87% dall'unità di cattura) e innalzarne il livello termico tramite pompe di calore con un COP di circa 2,7 può elettrificare completamente la rigenerazione del solvente. La soluzione tecnico-economica più promettente integra un'HTHP con una Ricompressione Meccanica del Vapore (MVR) e LVC. Questa configurazione produce un consumo specifico di energia elettrica di 474 kWh/tCO2 e minimizza il costo della CO2 evitata a 125,9 €/tCO2, rappresentando una riduzione del 16% rispetto alla baseline a gas naturale. Il CAPEX è stimato in 171,5 M€ (1,8 M€2024/tphCO2), ottenendo una riduzione del 32% del costo incrementale del clinker. Le analisi di sensibilità rivelano che, sebbene la competitività in termini di costo delle HTHP diminuisca all'aumentare dei prezzi dell'energia elettrica, esse rimangono valide in un'ampia gamma di condizioni, presentando l'ulteriore vantaggio di ridurre il consumo energetico a monte e le perdite di metano lungo la filiera di approvvigionamento del gas naturale. Il processo ibrido di cattura della CO2 proposto in questa tesi presenta un design che combina la combustione oxyfuel parziale e la CPU nel precalcinatore con un'unità PCC basata su MEA applicata ai fumi del forno rotativo e ai gas di sfiato della CPU. Un'analisi parametrica ha identificato un preriscaldatore a sospensione a tre stadi per entrambe le linee (forno e calcinatore), operante con una concentrazione di O2 del 50% nella corrente ossidante, come l'assetto più efficiente per il retrofit alla calcinazione oxyfuel parziale. Questo design sfrutta profonde sinergie termiche, poiché il calore di scarto disponibile dall'impianto fornisce circa 5,5 MJ/kgCO2, una quantità del tutto sufficiente per soddisfare il fabbisogno termico per la rigenerazione del solvente nell'unità ad MEA. Di conseguenza, il processo di cattura raggiunge l'autonomia termica senza la generazione ausiliaria di vapore, richiedendo energia elettrica esclusivamente per la fornitura di O2 e per i compressori di CO2. La configurazione ibrida consente tassi di riduzione della CO2 ultra-elevati, fino al 99,7%, e supera economicamente l'impianto di riferimento senza cattura in uno scenario di carbon tax di 150 €/tCO2, ottenendo un costo incrementale del clinker di 85,6 €/tclk e un costo della CO2 evitata di 103,6 €/tCO2. L'integrazione di combustibili alternativi migliora ulteriormente queste prestazioni; il passaggio dal carbone al 100% di combustibili derivati dai rifiuti (RDF) permette alla cementeria di operare come un impianto a emissioni nette negative, raggiungendo un'impronta carbonica di -181,9 kgCO2/tclk. È stato condotto un confronto completo rispetto ad altre tecnologie allo stato dell'arte, rivelando che mentre la configurazione oxyfuel parziale stand-alone (senza PCC sugli effluenti del forno) porta a un costo assoluto della CO2 evitata marginalmente inferiore, il processo ibrido diventa la soluzione con il minor costo incrementale del clinker quando la carbon tax supera i 115 €/tCO2. I maggiori CAPEX e OPEX dell'unità PCC del sistema ibrido sono efficacemente compensati dal volume significativamente più ampio di CO2 catturata, minimizzando le emissioni residue e riducendo i costi legati alla tassa sul carbonio. In definitiva, il processo ibrido si dimostra un'opzione sostanzialmente più valida economicamente ed efficiente dal punto di vista energetico rispetto alle soluzioni end-of-pipe basate su MEA. Per supportare la fase di ingegneria di dettaglio del progetto HERCCULES e le imminenti campagne sperimentali, sono state eseguite la modellazione di processo e termodinamica, oltre all'elaborazione dei dati sperimentali, per un'unità dimostrativa PCC con TRL 7. L'impianto pilota è progettato per trattare fumi di cementeria reali, producendo 125 kg/h di CO2 liquida con una purezza > 99% v/v. Integrando absorber intercooling, rich solvent split e la LVC, si registra una riduzione del 18% del consumo energetico equivalente rispetto alle configurazioni convenzionali. Il commissioning e la prima campagna di test utilizzando MEA al 30% in peso sono state completate con successo, con l'impianto che ha operato per oltre 800 ore e prodotto più di 20 tonnellate di CO2 liquida. Ventitré punti operativi a regime stazionario hanno confermato eccellenti prestazioni, con tassi di cattura della CO2 superiori al 99,5% e picchi vicini al 99,8%. La CO2 liquefatta ha soddisfatto i requisiti di qualità industriali e ISBT, mostrando livelli di impurità molto bassi. La campagna ha inoltre evidenziato una degradazione del solvente nel tempo, che potrebbe aver contribuito a prestazioni leggermente inferiori nei test successivi. Il confronto con il modello in Aspen Plus ha mostrato un buon accordo in merito ai parametri di processo chiave e ai trend operativi generali. Il fabbisogno termico stimato al ribollitore non è risultato in linea con la simulazione in Aspen e con i processi ad MEA allo stato dell'arte. I test futuri si concentreranno sul miglioramento del bilancio termico dell'impianto, sull'affinamento delle stime per la rigenerazione del solvente e sulla sperimentazione di configurazioni di processo e condizioni operative avanzate.
GATTI, MANUELE
File in questo prodotto:
File Dimensione Formato  
Cremona_PhD Thesis_final.pdf

non disponibili

Licenza: Tutti i diritti riservati
Dimensione 9.9 MB
Formato Adobe PDF
9.9 MB Adobe PDF

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14242/385228
Il codice NBN di questa tesi è URN:NBN:IT:POLIMI-385228