Effective proprioceptive feedback is a fundamental component of sensorimotor integration, supporting internal representations of body state that are essential for motor control, interaction with the environment, and the effective use of assistive devices such as prostheses. A wide range of approaches for restoring or augmenting proprioception have been explored, spanning both invasive strategies—such as peripheral nerve stimulation and intraneural interfaces—and non-invasive techniques, including vibrotactile, electrotactile, and skin stretch stimulation. However, existing systems often remain bulky, physically demanding, or require extensive training for reliable interpretation, limiting their practicality for everyday use and real-world tasks. In this context, non-invasive approaches offer a valuable testbed for the development and validation of proprioceptive feedback strategies and constitute the primary focus of this work, while also providing a pathway toward future invasive implementations. This thesis investigates proprioceptive feedback mechanisms, focusing on the hand and the wrist, and presents the design, implementation, and experimental validation of novel devices aimed at manipulating, enhancing, or restoring proprioceptive cues in able-bodied participants and prosthetic users. First, the relationship between skin deformation and finger joint kinematics was systematically quantified during grasping tasks. By combining motion capture of proximal and metacarpophalangeal joints with skin stretch measurements, we demonstrated a consistent and subject-independent relationship between joint angles and skin deformation. Building on this, we showed that hand kinematics can be accurately reconstructed from sparse skin stretch measurements using a functional principal component analysis (fPCA) framework combined with minimum-variance estimation, even when only a limited number of sensing locations are available. These findings motivated the design of the TWIST (Tactile Wearable Interface for Skin sTretch) wearable device, which delivers precisely controlled, non-invasive skin stretch stimulation across the proximal interphalangeal joint of the index finger. By controlling the stimuli delivered via TWIST, during active tasks and without local anaesthesia, we demonstrated for the first time that augmentation of the skin stretch that naturally occurs in grasping tasks can systematically bias perceived finger posture in voluntary movements. The investigation was then extended to the wrist to determine whether controlled skin stretch stimulation could produce intuitive proprioceptive cues on a larger articulation that is biomechanically and functionally critical for hand positioning, multi-planar movement, and fine object manipulation. A second wearable device was therefore designed following a detailed comparative study of different configurations. Each configuration was evaluated in terms of effective skin displacement and minimization of parasitic device motion, ensuring both mechanical stability and perceptual efficacy. The optimized wrist-worn device delivered stimuli consistent with flexion, extension, and supination movements. Experimental results showed that participants could interpret tactile cues reliably without prior training, with some reporting illusory wrist movements, indicating highly intuitive feedback. These findings highlight the importance of device design for translating proprioceptive signals into perceptually salient cues. The final contribution focuses on prosthetic applications of proprioceptive feedback, closing the sensorimotor feedback loop. The MISS (Magnetically Induced Skin Stretch) device, whose design is currently being evaluated for intellectual property protection, was developed as a non-invasive method capable of delivering magnetically mediated skin deformations synchronized with the movements of a soft anthropomorphic robotic prosthetic hand. Psychophysical experiments involved active manipulation tasks, where both able-bodied participants and transradial amputees controlled a myoelectric prosthesis to grasp objects. Results demonstrated high accuracy in object discrimination and effective proprioceptive perception, validating the system during active task conditions, also suggesting that MISS could pave the way toward invasive subcutaneous proprioceptive feedback delivery by serving as a promising experimental testbed. Complementary studies investigated transcutaneous electrical stimulation (TENS) as an additional non-invasive modality to enhance proprioceptive feedback with a myoelectrically controlled soft anthropomorphic prosthetic hand. In a series of pilot experiments with both able-bodied participants and a prosthetic user, TENS was applied to the finger flexor muscles, modulating hand posture during active manipulation tasks. The stimulation induced kinesthetic illusions and improved object discrimination performance, confirming its potential to enhance functional proprioceptive feedback in prosthetic control scenarios. Collectively, this thesis advances the understanding of cutaneous and sensorimotor contributions to proprioception and provides practical guidelines for the development of wearable and prosthetic feedback systems. By designing and validating three novel devices that deliver intuitive, functionally relevant proprioceptive cues, the thesis demonstrates how fundamental insights can be translated into applied human–machine interaction, thereby supporting real-world tasks such as prosthetic control, sensorimotor training in extended reality environments, and advanced human–robot interaction. These contributions offer strategies for restoring, augmenting, and tailoring proprioception in both clinical and everyday scenarios, and lay the groundwork for future investigations into hybrid non-invasive/invasive approaches and personalized sensory feedback in rehabilitation and assistive technologies.
Augmenting Human Proprioception via Wearable Devices: Implications for Advanced Human-Machine and Human-Robot Interaction
FONTANA, ELEONORA
2026
Abstract
Effective proprioceptive feedback is a fundamental component of sensorimotor integration, supporting internal representations of body state that are essential for motor control, interaction with the environment, and the effective use of assistive devices such as prostheses. A wide range of approaches for restoring or augmenting proprioception have been explored, spanning both invasive strategies—such as peripheral nerve stimulation and intraneural interfaces—and non-invasive techniques, including vibrotactile, electrotactile, and skin stretch stimulation. However, existing systems often remain bulky, physically demanding, or require extensive training for reliable interpretation, limiting their practicality for everyday use and real-world tasks. In this context, non-invasive approaches offer a valuable testbed for the development and validation of proprioceptive feedback strategies and constitute the primary focus of this work, while also providing a pathway toward future invasive implementations. This thesis investigates proprioceptive feedback mechanisms, focusing on the hand and the wrist, and presents the design, implementation, and experimental validation of novel devices aimed at manipulating, enhancing, or restoring proprioceptive cues in able-bodied participants and prosthetic users. First, the relationship between skin deformation and finger joint kinematics was systematically quantified during grasping tasks. By combining motion capture of proximal and metacarpophalangeal joints with skin stretch measurements, we demonstrated a consistent and subject-independent relationship between joint angles and skin deformation. Building on this, we showed that hand kinematics can be accurately reconstructed from sparse skin stretch measurements using a functional principal component analysis (fPCA) framework combined with minimum-variance estimation, even when only a limited number of sensing locations are available. These findings motivated the design of the TWIST (Tactile Wearable Interface for Skin sTretch) wearable device, which delivers precisely controlled, non-invasive skin stretch stimulation across the proximal interphalangeal joint of the index finger. By controlling the stimuli delivered via TWIST, during active tasks and without local anaesthesia, we demonstrated for the first time that augmentation of the skin stretch that naturally occurs in grasping tasks can systematically bias perceived finger posture in voluntary movements. The investigation was then extended to the wrist to determine whether controlled skin stretch stimulation could produce intuitive proprioceptive cues on a larger articulation that is biomechanically and functionally critical for hand positioning, multi-planar movement, and fine object manipulation. A second wearable device was therefore designed following a detailed comparative study of different configurations. Each configuration was evaluated in terms of effective skin displacement and minimization of parasitic device motion, ensuring both mechanical stability and perceptual efficacy. The optimized wrist-worn device delivered stimuli consistent with flexion, extension, and supination movements. Experimental results showed that participants could interpret tactile cues reliably without prior training, with some reporting illusory wrist movements, indicating highly intuitive feedback. These findings highlight the importance of device design for translating proprioceptive signals into perceptually salient cues. The final contribution focuses on prosthetic applications of proprioceptive feedback, closing the sensorimotor feedback loop. The MISS (Magnetically Induced Skin Stretch) device, whose design is currently being evaluated for intellectual property protection, was developed as a non-invasive method capable of delivering magnetically mediated skin deformations synchronized with the movements of a soft anthropomorphic robotic prosthetic hand. Psychophysical experiments involved active manipulation tasks, where both able-bodied participants and transradial amputees controlled a myoelectric prosthesis to grasp objects. Results demonstrated high accuracy in object discrimination and effective proprioceptive perception, validating the system during active task conditions, also suggesting that MISS could pave the way toward invasive subcutaneous proprioceptive feedback delivery by serving as a promising experimental testbed. Complementary studies investigated transcutaneous electrical stimulation (TENS) as an additional non-invasive modality to enhance proprioceptive feedback with a myoelectrically controlled soft anthropomorphic prosthetic hand. In a series of pilot experiments with both able-bodied participants and a prosthetic user, TENS was applied to the finger flexor muscles, modulating hand posture during active manipulation tasks. The stimulation induced kinesthetic illusions and improved object discrimination performance, confirming its potential to enhance functional proprioceptive feedback in prosthetic control scenarios. Collectively, this thesis advances the understanding of cutaneous and sensorimotor contributions to proprioception and provides practical guidelines for the development of wearable and prosthetic feedback systems. By designing and validating three novel devices that deliver intuitive, functionally relevant proprioceptive cues, the thesis demonstrates how fundamental insights can be translated into applied human–machine interaction, thereby supporting real-world tasks such as prosthetic control, sensorimotor training in extended reality environments, and advanced human–robot interaction. These contributions offer strategies for restoring, augmenting, and tailoring proprioception in both clinical and everyday scenarios, and lay the groundwork for future investigations into hybrid non-invasive/invasive approaches and personalized sensory feedback in rehabilitation and assistive technologies.| File | Dimensione | Formato | |
|---|---|---|---|
|
Augmenting_Human_Proprioception.pdf
embargo fino al 08/10/2029
Licenza:
Creative Commons
Dimensione
2.71 MB
Formato
Adobe PDF
|
2.71 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.14242/385761
URN:NBN:IT:UNIPI-385761