The PhD work involved three main biomedical research areas. In the first, we aimed at assessing whether T1 relaxometry measurements may help identifying structural predictors of mild cognitive impairments in patients with relapsing-remitting multiple sclerosis. Twenty-nine healthy controls and forty-nine RRMS patients underwent at high resolution 3T magnetic resonance imaging to obtain optimal cortical and white matter lesion count/volume as well as T1 relaxation times (rt). In WML and CL type I (mixed white-gray matter), T1 rt z-scores were significantly longer than in HC tissue (p<0.001 and p<0.01 respectively), indicating loss of structure. Multivariate analysis revealed T1 rt z-scores in CL type I were independent predictors of long term retrieval (p=0.01), T1 z-score relaxation time in white matter cortical lesions were independent predictors of sustained attention and information processing (p=0.02); In the second, we describe a biomagnetic susceptometer at room-temperature to quantify liver iron overload. By electronically modulated magnetic field, the magnetic system measure magnetic signal 108 times weaker than field applied. The mechanical noise of room-temperature susceptometer is cancelled and thermal drift is monitored by an automatic balance control system. We have tested and calibrated the system using cylindrical phantom filled with hexahydrated iron II choloride solution, obtaining the correlation (R=0.98) of the maximum variation in the responses of the susceptometer. These measures indicate that the acquisition time must be less than 8 seconds to guarantee an output signal variability to about 4-5%, equal to 500ugr/grwet of iron. In the third, a 3D anatomically detailed finite element analysis human foot model is final results of density segmentation 3D reconstruction techiniques applied in Computed Tomography(CT) scan DICOM standard images in conjunctions with 3D finite element analysis(FEA) modeling. In this model the real morphology of plantar fat pad has been considered: it was shown to play a very important role during the contact with the ground. To obtain the experimental data to compare the predictions of 3D foot model, a posturography static examination test on a baropodometric platform has been carried. The experimental plantar contact pressure is, qualitatively, comparable with FEA predicted results, nominally, the peak pressure value zones at the centre heel region and beneath the metatarsal heads.
Multimodal techniques for biomedical image processing
AMARU', Fabio
2014
Abstract
The PhD work involved three main biomedical research areas. In the first, we aimed at assessing whether T1 relaxometry measurements may help identifying structural predictors of mild cognitive impairments in patients with relapsing-remitting multiple sclerosis. Twenty-nine healthy controls and forty-nine RRMS patients underwent at high resolution 3T magnetic resonance imaging to obtain optimal cortical and white matter lesion count/volume as well as T1 relaxation times (rt). In WML and CL type I (mixed white-gray matter), T1 rt z-scores were significantly longer than in HC tissue (p<0.001 and p<0.01 respectively), indicating loss of structure. Multivariate analysis revealed T1 rt z-scores in CL type I were independent predictors of long term retrieval (p=0.01), T1 z-score relaxation time in white matter cortical lesions were independent predictors of sustained attention and information processing (p=0.02); In the second, we describe a biomagnetic susceptometer at room-temperature to quantify liver iron overload. By electronically modulated magnetic field, the magnetic system measure magnetic signal 108 times weaker than field applied. The mechanical noise of room-temperature susceptometer is cancelled and thermal drift is monitored by an automatic balance control system. We have tested and calibrated the system using cylindrical phantom filled with hexahydrated iron II choloride solution, obtaining the correlation (R=0.98) of the maximum variation in the responses of the susceptometer. These measures indicate that the acquisition time must be less than 8 seconds to guarantee an output signal variability to about 4-5%, equal to 500ugr/grwet of iron. In the third, a 3D anatomically detailed finite element analysis human foot model is final results of density segmentation 3D reconstruction techiniques applied in Computed Tomography(CT) scan DICOM standard images in conjunctions with 3D finite element analysis(FEA) modeling. In this model the real morphology of plantar fat pad has been considered: it was shown to play a very important role during the contact with the ground. To obtain the experimental data to compare the predictions of 3D foot model, a posturography static examination test on a baropodometric platform has been carried. The experimental plantar contact pressure is, qualitatively, comparable with FEA predicted results, nominally, the peak pressure value zones at the centre heel region and beneath the metatarsal heads.File | Dimensione | Formato | |
---|---|---|---|
PhDThesis_FABIO_AMARU_Imaging_XXVIcycle_2011.pdf
accesso aperto
Dimensione
4.57 MB
Formato
Adobe PDF
|
4.57 MB | Adobe PDF | Visualizza/Apri |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.14242/112972
URN:NBN:IT:UNIVR-112972