The research followed consist mainly on the use of passive methods for dynamic characterization of soil and building. Local Seismic Response of the construction site and Calibration of FE model of a reinforced concrete building have been performed. Passive seismic measurements have been acquired by two portable seismographs synchronized by each other with GPS antenna. Subsequently, structural verifications (global structural response) have been realized using once the response spectrum estimated from Local Seismic Response and once from technical standards. Finally, confronts between results have been realized at the aim to evaluate the importance of local seismic response of soil.

PASSIVE METHOD FOR DYNAMIC CHARACTERIZATION OF SOIL AND BUILDINGS

XHIXHA, ELONA
2017

Abstract

The research followed consist mainly on the use of passive methods for dynamic characterization of soil and building. Local Seismic Response of the construction site and Calibration of FE model of a reinforced concrete building have been performed. Passive seismic measurements have been acquired by two portable seismographs synchronized by each other with GPS antenna. Subsequently, structural verifications (global structural response) have been realized using once the response spectrum estimated from Local Seismic Response and once from technical standards. Finally, confronts between results have been realized at the aim to evaluate the importance of local seismic response of soil.
2017
Inglese
Ambient vibration tests, Dynamic characterization, Modal analysis, Finite element modal updating, Operational modal analysis
ALBARELLO, DARIO
Università degli Studi di Siena
256
File in questo prodotto:
File Dimensione Formato  
Tesi PhD_E.Xhixha.pdf

accesso aperto

Licenza: Tutti i diritti riservati
Dimensione 19.22 MB
Formato Adobe PDF
19.22 MB Adobe PDF Visualizza/Apri

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14242/88022
Il codice NBN di questa tesi è URN:NBN:IT:UNISI-88022